This paper deals with specifying and evaluating fans for mine ventilation projects. Topics such as fan and equipment design life, operating points, and operating conditions are discussed. Common operating problems, such as vibration, parallel operation, mechanical failure, erosion, corrosion, and deficient fan performance are covered. Apart from identifying the potential operating problems, likely causes and suggested remedies are given. Fan type, fan accessories, and likely system effects and fan testing are discussed. Suggestions on what should be covered when evaluating different
fan options and proposals and suggestions on the verification of supplier claims and guarantees, including cost of operation, the evaluation of initial capital cost, estimate on maintenance costs, and likely replacement expenditure over the life of the fans. In addition, fan reliability, operational flexibility, suggested construction details and fan vendor past
history and experience are reviewed.